Logo Tropentag

Tropentag, September 17 - 19, 2014 in Prague, Czech Republic

"Bridging the gap between increasing knowledge and decreasing resources"


Prediction of Water Content in Indonesian Green Coffee Beans Using near Infrared Spectroscopy

Adnan1, Dieter von Hörsten2, Daniel Mörlein3, Elke Pawelzik1

1Georg-August-Universität-Göttingen, Dept. of Crop Sciences: Inst. Quality of Plant Products, Germany
2Julius-Kühn-Institute, Institute for Application Techniques in Plant Protection, Germany
3Georg-August-Universität-Göttingen, Dept. of Animal Sciences, Germany


Abstract


Water content in green coffee bean is one of the most important factors with direct influence on its quality. Usually, water content is analysed using a gravimetric method including 16-24 h oven drying. The aim of this study is to evaluate the feasibility of near infrared spectroscopy (NIR) for non-destructive and fast prediction of water content in Indonesian green coffee beans using multivariate analysis. Green coffee beans were obtained from different origins in Indonesia, n=5 for Arabica and n=7 for Robusta. Coffee beans were placed in a climacteric chamber at 25°C and relative humidity (RH) of 30-85% in order to obtain a wide range of water content. NIR spectra were collected using a bench top Fourier transform (FT) NIR instrument in the wavelength range of 1000–2500 nm in diffuse reflectance (log 1/R) mode. Water content was analysed according to ISO 6673 as reference. NIR spectra were collected from 108 samples, n=64 for calibration and n=44 for prediction. Partial least squares regression (PLSR) using raw data with 3 latent variables factors yielded the best prediction with coefficients of determination (R2) for calibration, cross validation, and prediction of 98.3%, 97.9%, and 96.4%, respectively. Weighted regression coefficients from PLSR revealed that the wavelengths 1409, 1724, 1908 and 2249 nm are highly correlated with the water content. Using these selected wavelengths for multiple linear regression (MLR) yielded R2 for calibration, cross validation, and prediction of 97.6%, 96.9%, and 97.3%, respectively. To conclude, NIR combined with chemometrics is a promising method for rapid and reliable water content prediction in green coffee beans.


Keywords: Coffee bean, MLR, near infrared, PLSR, water content


Contact Address: Adnan, Georg-August-Universität-Göttingen, Dept. of Crop Sciences: Inst. Quality of Plant Products, Carl-Sprengel-Weg 1, 37075 Göttingen, Germany, e-mail: adnan.adnan@stud.uni-goettingen.de


Valid HTML 3.2!